Artificial Heart Valve System Device Developer
LONDON — For patients with severe tricuspid regurgitation, treatment options have long been limited. The condition, where blood leaks backward through the heart's tricuspid valve, often strikes those too frail for open-heart surgery. Now, early clinical data from a European study suggest a transcatheter replacement device developed by China's Venus Medtech may offer a meaningful alternative.
The company disclosed six-month results from its TARGET study at the PCR London Valves 2026 conference, showing that 76.7% of evaluable patients (120 of 157 enrolled) had no or only trace tricuspid regurgitation at the six-month mark. That figure held steady through three years of follow-up at 76.9%, based on 26 evaluable patients.
The TARGET study is a prospective, single-arm, multi-center trial conducted across nearly 30 cardiovascular centers in Germany, Spain, Italy, the United Kingdom and Canada. It was designed to evaluate the safety and clinical performance of the Cardiovalve transcatheter tricuspid valve replacement system — or Cardiovalve TR System — the company's proprietary device.
The system met both its primary performance endpoint and primary safety endpoint, Venus Medtech (Hangzhou) Inc. said.
Functional Gains That Hold
Patients in the study showed measurable improvements in functional status, exercise capacity and quality of life that persisted through follow-up.
At one year post-implant, the average six-minute walk distance improved by 42 meters. The Kansas City Cardiomyopathy Questionnaire (KCCQ) score rose by an average of 20 points at the same timepoint — a clinically meaningful gain for heart failure patients.
By the three-year mark, 80% of patients were classified as New York Heart Association (NYHA) functional class I or II, up from 39.9% at baseline.
The right side of the heart also showed signs of positive reverse remodeling. At three years, the diameter of the inferior vena cava decreased by an average of 25%, the right ventricular end-diastolic diameter at the mid-segment fell by 22%, and the basal segment dropped by 11%.
Safety Profile Improves With Newer System
At 30 days post-procedure, the all-cause mortality rate stood at 5.7%. Heart failure rehospitalization was 1.9%, and major access-site and vascular complications requiring surgical intervention occurred in 5.1% of patients.
Notably, the enhanced delivery system showed substantial safety gains over the first-generation system. Major bleeding events fell from 21% to 5.0%, and major vascular complications dropped from 8.8% to 3.0%.
Design Choices That Matter
The Cardiovalve TR System is designed to be delivered via a transfemoral venous approach — through the femoral vein in the leg — which the company says significantly improves procedural safety compared with competing products.
The device accommodates valve annuli up to 55 millimeters, covering roughly 95% of the patient population. Its short valve frame is engineered to reduce the risk of ventricular outflow tract obstruction, a known complication of tricuspid interventions.
The procedure itself requires just three steps — positioning, anchoring and release — a simplicity that may aid adoption among interventional cardiologists.
What Comes Next
The six-month full-cohort results and up to three years of follow-up data reinforce the device's sustained clinical benefit and long-term durability in high-risk patients with severe tricuspid regurgitation.
Venus Medtech said it will continue pushing forward with CE marking certification for the Cardiovalve TR System and expand clinical adoption globally, leveraging its research, manufacturing and commercial capabilities in structural heart disease.
For the roughly 157 patients enrolled — and the millions worldwide living with tricuspid valve disease — the question now is whether these early gains can be replicated at scale.