Developer of products in the field of cardiac electrophysiology
Click Blue Words

Follow us

Recently,The Second Affiliated Hospital of Zhengzhou UniversityAs one of the first clinical application units in China, byDirector of Cardiology Sun Liqiang and Attending Physician Zhao JiajiaApplication of AccuPulse Medical®Single-use Cardiac Pulse Electric Field Ablation Catheter and AccuBlator®The cardiac pulsed electric field ablation system successfully performed a pulsed field ablation (PFA) procedure on a patient with atrial fibrillation.
The successful completion of the surgery not only marks the official entry of this innovative domestically-produced PFA system into the clinical application stage, but also, with its three core advantages of integrated circular catheter mapping and modeling, efficient ablation, and excellent safety, provides a better option for atrial fibrillation interventional treatment.
Case Brief
The patient is a 57-year-old male with paroxysmal atrial fibrillation. Based on preoperative examinations, the AccuPulse 20-25mm adjustable loop cardiac pulsed field ablation catheter was selected. Its integrated design for mapping, modeling, and ablation enabled the operator to quickly complete three-dimensional left atrial modeling and mapping in just 15 minutes, with a total pulmonary vein ablation time of only 17.15 seconds, significantly enhancing the safety of the procedure.

Atrial Premature Excitation Mapping

Upper Cavity Pulse Ablation Diagram
The ablation process first targets the origin of premature atrial contractions in the left inferior pulmonary vein, followed by consolidation ablation of the left pulmonary vein. After 6 rounds of ablation, the premature atrial contractions disappeared. Then, 6 more rounds of consolidation ablation were performed, followed by pulmonary vein isolation ablation.


Schematic Diagram of Substrate Mapping Before and After Ablation


ECG Comparison Before and After Ablation
Postoperative substrate mapping, pulmonary vein potential recording, and other comprehensive evaluation results showed that complete electrical isolation of the pulmonary veins was achieved, and bidirectional conduction block was firmly established. High-frequency burst stimulation performed postoperatively did not induce any sustained arrhythmias, strongly demonstrating that the AccuPulse PFA system not only achieved immediate successful ablation but also effectively reduced the risk of atrial fibrillation recurrence in patients.
Expert Commentary

The team highly recognized the comprehensive performance of AccuPulse’s adjustable ring PFA catheter, specifically pointing out that the adjustable ring design has a wider range of use, can adapt to more complex anatomical structures, and offers higher ablation efficiency with excellent clinical applicability.
The operator further shared their personal experience: the catheter itself is an excellent product with a short learning curve and easy to handle. The complete success of this surgery marks that the significant advantages of AccuPulse’s PFA adjustable loop catheter in operational flexibility and efficient ablation have gained deep recognition from clinical experts, laying a solid foundation for its widespread application in the field of atrial fibrillation treatment.
About AccuPulse Cardiac Pulse Ablation System
Flexible Adaptation, Precise Contact:Its unique 7.5F adjustable loop diameter design can flexibly match the pulmonary vein anatomy of different patients, achieving personalized adaptation and significantly improving the adaptability and safety of the operation.
Intelligent docking, real-time feedback:The system is equipped with AccuPulse's self-developed impedance contact prompting technology, which can monitor the catheter-tissue contact quality in real time, clearly indicate the contact status, assist operators in achieving stable and reliable catheter manipulation, and provide a solid guarantee for precise ablation.
Efficient Integration, Streamlined Processes:The circular catheter integrates mapping, modeling, and ablation functions, rapidly constructing a three-dimensional electroanatomical model of the heart during surgery, precisely locating lesions, and significantly reducing reliance on additional high-density mapping catheters in traditional surgeries. This not only decreases surgical complexity but also saves on consumable costs, providing atrial fibrillation patients with a safer, more effective, and less invasive treatment option.
Safer:7.5F Ultra-thin Catheter, Reducing Tissue Damage
More Stable:Smart Snap Tips for More Precise Operation
More flexible:Adjustable loop diameter (15-20mm or 20-25mm) to meet different clinical choices.

AccuPulse Medical Technology Co., Ltd. has received approval for its disposable cardiac pulsed field ablation catheter, which overcomes the challenges of catheter stability and anatomical adaptability in the PFA field, providing a precise and reliable solution for pulmonary vein isolation (PVI). The unique 7.5F adjustable loop diameter design of the AccuPulse cardiac pulsed field ablation catheter flexibly addresses pulmonary vein ablation in different anatomical structures. Intelligent contact indication and flexible electrode selection give operators complete control, enabling precise pulsed field ablation!
The successful application of PFA technology this time is an important achievement of AccuPulse in the continuous innovation and dedicated efforts in the field of atrial fibrillation treatment. The system's efficiency, safety, and potential cost-effectiveness demonstrated during the procedure show broad clinical application prospects and market potential. In the future, AccuPulse will continue to deepen clinical collaboration with the Second Affiliated Hospital of Zhengzhou University, promote the standardized application and popularization of PFA technology, and strive to provide internationally leading one-stop atrial fibrillation diagnosis and treatment solutions for arrhythmia patients across China.
About AccuPulse Medical
AccuPulse Medical Technology Co., Ltd. is an innovative company based in Suzhou that focuses on the research, development, and industrialization of advanced technologies in the field of cardiac electrophysiology. The company's core team possesses deep expertise in electrophysiological technology and extensive experience in the industrialization of medical devices, consistently striving to provide safer, more efficient, and more convenient treatment options for patients with arrhythmias such as atrial fibrillation.
This time, AccuPulse®Single-use Cardiac Pulsed Field Ablation Catheter and AccuBlator®The successful application of the cardiac pulsed electric field ablation system at the Second Affiliated Hospital of Zhengzhou University marks a milestone achievement for AccuPulse in the field of innovative electrophysiology treatment technologies.
Expert Profile
Sun Liqiang
The Second Affiliated Hospital of Zhengzhou University
Department of Cardiovascular Medicine, Chief Physician, has been engaged in interventional diagnosis and treatment of heart diseases for many years. Completed advanced studies in the diagnosis and treatment of critical illnesses in cardiology and interventional diagnosis and treatment of coronary heart disease at Fuwai Cardiovascular Hospital of Beijing Medical Academy and People's Hospital of Peking University. Has rich experience in the diagnosis and treatment of coronary heart disease, hypertension, arrhythmia, cardiomyopathy, valvular heart disease, and heart failure.
Participated in 4 national-level scientific research projects and 5 provincial/municipal-level scientific research projects. Published 1 SCI paper, 2 papers in Chinese Journal, and more than 10 papers in core journals. Authored "Modern Cardiology Diagnosis and Treatment Techniques and Practice." Youth Committee Member of the Electrophysiology and Pacing Branch of the Henan Provincial Biomedical Engineering Society; Committee Member of the Cardiovascular Rehabilitation Branch of the Henan Provincial Rehabilitation Medical Association; Deputy Secretary-General of the Cardiovascular Disease Prevention and Rehabilitation Branch of the Henan Provincial Biomedical Engineering Society; Committee Member of the Cardiovascular Branch of the Henan Provincial Microcirculation Society; Committee Member of the Cardiac Critical Care Group of the Henan Provincial Medical Association.
Zhao Jiajia
The Second Affiliated Hospital of Zhengzhou University
Cardiovascular Medicine Department, Attending Physician, has published dozens of papers, presided over 4 ongoing research projects, and serves as a committee member of the Cardiovascular Disease Prevention and Rehabilitation Committee of the Henan Province Biomedical Engineering Society, a committee member of the Hypertension Group of the Cardiovascular Physicians Branch of the Henan Province Medical Doctor Association, a committee member of the Basic Pacing Electrophysiology Branch of the Henan Province Biomedical Engineering Society, a committee member of the Cardiovascular Disease Rehabilitation Branch of the Henan Province Rehabilitation Medical Association, and a committee member of the Cardiovascular Branch of the Henan Geriatrics and Geriatric Medicine Society. Skilled in the diagnosis and treatment of common cardiovascular diseases, proficient in coronary intervention therapy, catheter radiofrequency ablation, pulsed field ablation, left atrial appendage closure, and esophageal balloon protection-assisted radiofrequency ablation. Specializes in green electrophysiological procedures, including: zero-radiation supraventricular tachycardia (SVT), premature ventricular contractions (PVCs), and atrial fibrillation (AF) radiofrequency ablation. Successfully conducted China's first batch of AF pulsed field ablation and SVT pulsed field ablation! Awarded the first prize in the "2025 Zhijiang Heart Rhythm and Circulation Forum" Dongfang Cup National Esophageal Cardiac Electrophysiology Knowledge Competition!