
Cardiovascular Interventional Device Developer
LaaGuarder™ QiLong® Left Atrial Appendage Occluder SystemTo be obtained by early 2025 as the first domestically producedCE MDR Certificate, This successful implantation for patients with paroxysmal atrial fibrillation at high risk of stroke in Italy marks a further expansion of domestically developed products in the international market.

Mercogliano, Italy — January 26, 2026, Shenqi Medical Technology Co., Ltd.LaaGuarder™ QiLong® Left Atrial Appendage Occluder SystemSuccessfully Completed the First Clinical Application at Clinica Montevergine, a Cardiac Specialty Hospital in Italy.
The surgery was successfully led by Professor Luigi Salemme, with the left atrial appendage closure device remaining stable post-operation and no other complications reported. Professor Luigi Salemme highly praised the quality, performance, and clinical outcomes of the device, expressing hope that this product will offer a better treatment option for more atrial fibrillation patients in Europe.
As the first domestically developed left atrial appendage occluder system in China to receive CE MDR certification, the successful completion of this surgery marks the official start of its global journey, demonstrating the global competitiveness of China's innovative medical devices.
Case Sharing
This patient is an elderly male with paroxysmal atrial fibrillation, posing a high risk of stroke and bleeding. Preoperative transesophageal echocardiography indicated no thrombus in the left atrium and left atrial appendage.

TEE Evaluation of Left Atrial Appendage Thrombus
The left atrial appendage of this case is a bifoliate cauliflower type, with an opening of about 20mm and a depth of about 18mm. Therefore, a 27mm model was selected.LaaGuarder™ QiLong® Left Atrial Appendage Occluder System。

Position RAO30° CAU20° Left Atrial Appendage Angiography

TEE 3D Left Atrial Appendage Orifice Diameter Measurement
The left atrial appendage occluder was implanted in a suitable position, with stable traction, a compression ratio of 29%, no residual shunt, and no other complications.

Deployment of Occluder Under DSA

Ultrasound after occluder release
The successful clinical implantation this time demonstrated the safety and efficacy of the product, further advancing Shenqi Medical's international strategic layout to the next stage. The LaaGuarder™ Qi Long® Left Atrial Appendage Occluder System will work in synergy with peripheral coils, microcatheters, coronary drug-coated balloons, and cutting balloons to further deepen Shenqi Medical’s international market strategy deployment in the three fields of structural heart disease, peripheral intervention, and coronary intervention, accelerating global expansion.

As a medical enterprise rooted in China, Shenqi Medical adheres to the concept of "Innovation · Heart Protection" and always takes "better meeting the rapidly growing healthcare needs of the Chinese market" as its mission. By developing innovative, high-quality cardiac and vascular interventional products, it provides comprehensive solutions in the field of cardiovascular disease treatment, benefiting more patients in China. In the future, Shenqi Medical will position and develop its products for the global market, actively participate in global competition in related fields, and commit to launching more high-quality and advanced medical device products, providing more comprehensive disease treatment solutions for patients both domestically and internationally.
