
Chronic Disease Medical Device and Therapy Developer

Heart to the Future
Recently,Hackensack Meridian Jersey Shore University Medical CenterAnnouncementParticipate in Medtronic's APOLLO Clinical Trial, the trial is ongoingEvaluationIntrepid Transcatheter Mitral Valve Replacement System (TMVR)Safety and Effectiveness, inTreatment for patients with moderate to severe or severe symptomatic mitral regurgitation (MR) who are not suitable for transcatheter repair or surgery. This isOne of the only two hospitals in New Jersey providing this trial to patients。

As part of a global clinical trial,The Intrepid valve has been used to treat more than 350 patients.。
Currently, Medtronic's APOLLO trial is evaluating the Intrepid TMVR system for use in patients with severe mitral regurgitation (MR).An experimental groupEvaluationPatients with primary or secondary mitral regurgitation who are not suitable for traditional mitral valve surgery or transcatheter edge-to-edge repair (TEER);Another experimental groupEvaluationPatients with severe symptoms of mitral regurgitationThese patients are considered unsuitable for conventional surgery for mitral annular calcification (MAC).
So far, patients participating in this study have received the Intrepid TMVR system,The system usesThrough the apex approach, compressing the valve within a hollow catheter, then transmitting it through the ribs to the heart.。
With the approval of the Investigational Device Exemption (IDE), APOLLO researchers will have an additional option,That is, the valve is inserted into the femoral vein through an inguinal incision.,This is the majority of transcatheter proceduresPreferred Method。Meanwhile,Intrepid valve is also undergoing early feasibility trial research in the tricuspid field., Medtronic is trying to find new technologies to crack the难题.
# Intrepid Transcatheter Mitral Valve Replacement System

▲Intrepid Transcatheter Mitral Valve Replacement System (Image SourceOfficial CompanyNet)
Intrepid Valve AdoptedDouble-layer Stent DesignThe outer stent is soft and contains barbs, which can pierce into the mitral valve leaflets to secure the entire device in place; the inner stent serves as the functional stent, with three bovine pericardial leaflets sutured inside.
Both stents are cylindrical in shape,The peripheral stent can deform with cardiac contraction., to reduce left ventricular outflow tract obstruction and protect the contractile function of the cardiac base;Internal stents can also avoid interference from external stents., thereby better enhancing the function of the valve. Additionally, the design of the peripheral stent can also make the diameter of the artificial valve ring smaller,Reduce the stress on the valve leaflets, thereby extending the life of the valve.(The lifespan of bioprosthetic valves is related to both the height of the leaflet suspension and the valve orifice area.)
# Product Features and Analysis
(1) Minimal trauma
Intrepid Transfemoral Approach vs. Transapical ApproachCan significantly reduce intraoperative trauma to patientsHowever, according to the 2021 TCT report, the incidence of vascular complications with the femoral vein approach version of Intrepid was as high as 40% (6/15), which may be mainly due to the large delivery outer diameter (35F) of the entire system. Therefore,The Intrepid system will further reduce the outer diameter of the entire delivery system to 29F in order to reduce vascular complications.。

▲Image SourceOfficial CompanyNet
(2) Stable Anchoring
The mitral valve has complex working conditions compared to the aortic valve. The position of the mitral valve and the structure of the mitral annulus increase the difficulty of accurately placing an artificial valve, and the implanted valve needs to remain stable without displacement.
The anchoring methods of TMVR include end tethers (Abbott Tendyne); radial interference (Medtronic Intrepid); barbs (Medtronic Intrepid); anchoring arms (Edwards Evoque); valve-in-ring (Edwards Sapien M3 and Highlife), etc.Medtronic's Intrepid adopts a dual-anchor mode with radial interference and barbs.Success rate of femoral valve anchoring: 93%One patient was converted to surgery due to valve displacement after implantation.

▲Image SourceOfficial CompanyNet
(3) Avoid paravalvular leakage
Similar to aortic valve design, almost all TMVR valves currentlyAll adopt the method of using sealing membranes to prevent paravalvular leakage., but the complex D-shaped three-dimensional saddle structure of the mitral valve annulus poses a significant challenge for valve design.
Medtronic'sIntrepid valve adopts a dual-layer stent design with inner and outer frames., the outer stent is sutured with a dense sealing membrane, and the outer stent is relatively soft and contains multiple rows of barbs. After the valve is released, the barbs on the outer stent can penetrate into the native valve leaflets,Not only can it serve as an anchor, but also the larger skirt seal can effectively prevent paravalvular leakage.; The inner stent is sutured with three bovine pericardial leaflets, which play a role in opening and closing during the diastole and systole of the heart.
CurrentlyMedtronic's Intrepid Valve PossessesTwo sizes: 42mm and 48mm, the 54mm size valve is under development, where 42mm, 48mm, and 54mm refer to the outer stent sizes, while the inner stent is only available in a single 27mm size.

▲Image SourceOfficial CompanyNetwork
(4) Avoid outflow tract obstruction
Medtronic's Intrepid valve has a dual-layer frame with both inner and outer layers featuring a circular structure.The outer stent can change with cardiac contraction, effectively reducing left ventricular outflow tract obstruction.;The inner stent is not interfered with by the outer stent., which can protect bovine biological tissue valves,Ensure Blood Flow Direction。
Early Intrepid patients were selected using the end-systolic assessment method.Left Ventricular Outflow Tract Area (Neo-LVOT),The screening failure rate is as high as 40%.,With the continuous progress of clinical trials and the accumulation of operators' experience, researchers have adopted multi-phase evaluation methods and early systolic evaluation methods to assess Neo-LVOT for patients who were initially excluded.Significantly increased the proportion of patient enrollment,Screening failure rate drops to 20%。
With the continuous improvement of equipment and the accumulation of operators' experience, such as avoiding LVOT through alcohol septal ablation and anterior mitral leaflet laceration (LAMPOON), it is believed that more and more patients with mitral regurgitation will benefit from TMVR in the future, significantly improving their quality of life.

▲Image SourceOfficial CompanyNet
# Results of Early Feasibility Study
Early Clinical Study Results of the Intrepid Transfemoral Mitral Valve Replacement System Reported on 26 Selected PatientsFinally, 15 patients completed the implantation., one patient converted to open chest surgery. The ratio of primary regurgitation to secondary regurgitation was approximately 2:1, with an average patient age of 80 years, and most cases were severe mitral regurgitation.
The data shows Intrepid's strong ease of use and the advantages of the transfemoral approach.The average instrument operation time was 46 minutes, and the average postoperative hospital stay was 5 days.The 30-day postoperative follow-up results also demonstrated the superior treatment outcomes of Intrepid.All-cause mortality rate in 15 patients is 0%。The incidence of stroke, reintervention (or surgery), pacemaker implantation, and renal impairment events of grade 2 or higher was 0.. Immediately after the operation, mitral regurgitation decreased to trace or less (MR≤1+) in all patients.100% of patients had complete disappearance of mitral regurgitation 30 days after surgery。


▲Image SourceOfficial CompanyNet
AboutMedtronic

Medtronic (Medtronic, NYSE: MDT), founded in 1949, is headquartered in Minneapolis, Minnesota, USA. It is a global leading medical technology company dedicated to providing lifelong treatment solutions for patients with chronic diseases.With over 95,000 employees,Innovative solutions have expanded to more than 70 key disease areas.。
Main Products of MedtronicCoverageArrhythmia, Heart Failure, Vascular Disease, Heart Valve Replacement, Extracorporeal Cardiac Support, Minimally Invasive Cardiac Surgery, malignant and non-malignant pain, ataxia, diabetes, gastrointestinal diseases, urinary system diseases, spinal diseases, neurological disorders, and surgeries in ophthalmology, otolaryngology, and stomatology.
Medtronic|J&J MedTech|Boston ScientificBoston Scientific|
Edwards Lifesciences | AbbottAbbott|
# Chinese Cardiovascular Device Companies Listed in China
XinQing Medical (NyokAssist Interventional Ventricular Assist System)
Beixins Life (Cardiac Pulse Field Ablation)
Hanling Medical (Transcatheter Aortic Valve)
# Other Unlisted/Start-up Cardiovascular Companies
Artivion| HVR Cardio | CardiacSense | Lydus Medical | Volta Medical |Cardiac Dimensions
